Re-encrypting the same 17 passages at period thirteen cut recovery from 17/17 to 8/17, even when thirteen was a permitted period. A model restricted to periods three through eight recovered none of the thirteen-slot blind endings.
| Planted period | Search periods 3–8 | Search periods 3–8 and 13 |
|---|---|---|
| Short, cycled 3–8 | 17/17 | 17/17 |
| Exactly 13 | 0/17 | 8/17 |
This was a matched change to the key, not to the text length, language model, candidate cap, or grade window. We searched the best 32 nominal keys for each allowed length under the rune-pair score, reduced equivalent repeated cycles, charged one log(29) per independent slot, and retained four finalists. Word scores on fresh ciphertext then chose the winner. For the long-key cases, every panel that contained an exact ending chose it. The other nine panels lacked it.
The 48-rune confirmation length covers every key slot twice across complete words on the unsolved layouts under the earlier no-pause model. That length does not guarantee that the separate 72-rune nomination segment identifies a 13-slot key. The missing candidates, and the costs of increasing width, are measured independently in Session 170.