# Session 409: Is ordinary contrast adjustment enough?

A contrast curve forced to increase with source darkness is worse than one allowed to turn back down.

We held the successful tone model’s geometry and smoothing fixed. A monotonic control was then learned on training pixels with fifty bins and count-weighted isotonic regression. This permits flexible contrast, but prevents a darker input from becoming lighter than a paler input.

On the held-out right the monotonic model scores 0.857, compared with 0.910 for the turning curve; on the left it scores 0.797 versus 0.877. The effect is clearest in the center crown, used by neither side for training: about 0.56 for the monotonic model, against about 0.90 for the turning curve. The result favors a non-monotonic tone relationship on the crown; it is not a unique historical recipe.

[Center and stable-loop results](transfer_409_results.json) · [Code](transfer_409.py).